d glass will remain in place.
In event of fire, it replies to smoke barrier needs, without producing
flaming droplets.
System available in 2 different classifications
DH 30 / DH 30 SAFE
30 minutes standard heating fire curve (ISO 834)
Max dimensions (w ⊗ h): 2000 ⊗ 1100 mm (landscape)
1000 ⊗ 1600 mm (portrait)
D 120 / D 120 SAFE
120 minutes reduced heating fire curve up to 600°C
Max dimensions (w ⊗ h): 2500 ⊗ 1800 mm (landscape)
Dimension (mm)
D 120
W
≤ 2000
≤ 1000
≤ 2500
D
≤ 1100
≤ 1600
≤ 1800
W1
≤ 350
≤ 250
≤ 350
W2
≤ 1300
≤ 500
≤ 1800
Fitting
2/glass
2/glass
2/glass
with & without
with & without
with & without
“SAFE” option
Application
DH 30
Availability: 6 mm thickness glass
Smoke reservoir boundaries, channeling screens, corridor
containment, escalator and elevator containment. These smoke
protection systems are applied as ceiling glazing with the
purpose, in case of fire, to block the passage of smoke or heat
f ... ascunde
Pentru noi, confidențialitatea dvs. este importantă
Portalul spatiulconstruit.ro folosește cookies pentru a asigura funcționalitatea și securitatea site-ului, pentru a personaliza conținutul și modul de interacțiune, pentru a oferi facilități de social media
și pentru a analiza modul în care este utilizat site-ul. Aceste cookies sunt stocate și prelucrate, de către noi sau partenerii noștri în conformitate cu toate reglementările în vigoare și toate standardele
de confidențialitate și securitate actuale.
Vă rugăm să rețineți că este posibil ca anumite prelucrări ale datelor dumneavoastră cu caracter personal să nu necesite consimțământul dumneavoastră, dar vă puteți exprima acordul cu privire la prelucrarea
realizată de către noi și partenerii noștri conform descrierii de mai sus utilizând butonul SUNT DE ACORD de mai jos.
Navigând în continuare, vă exprimați acordul implicit asupra folosirii cookie-urilor.