Profile de dilatatie pentru pereti, pardoseli VEDA Joint Covers & compression profiles
Joint covers
Presentation
The clips af¿xed joint covers are designed to provide an attractive and decorative low cost solution to the problem of protecting and concealing expansion joints in the structure of a building. They are suitable for use in new and refurbishment projects for walls, ceilings and Àoors.
CLIPS AFFIXED JOINT COVERS FOR STANDARD AND SEISMIC STRUCTURAL MOVEMENT JOINTS
Extruded Aluminium The extruded aluminium clips af¿xed joint covers for expansion joints can be used for exteriors and interiors. They are manufactured from 6063 T6 Aluminium alloy and can be ¿nished with a 15 micron thick natural (colourless) anodising layer. They are available from stock in 3 meters lengths and following widths:
1. Insert a fastening clip
Fast and easy to install, the clips af¿xed joint covers are produced in aluminium, PVC and brass extrusions. They will successfully span joints up to 150 mm in all types of buildings: of¿ce buildings, shopping centres, schools, hospitals, hot
els, blocks of Àats, retail development, food stores, municipal buildings, leisure centres, factories, airport terminals, rail terminals, etc…
Flat models :
- 50 mm, 60 mm, 70 mm, 90 mm, 120 mm, 140 mm, 180 mm and 210 mm
Angle models :
- 50 mm, 60 mm, 70 mm, 90 mm and 120 mm Aluminium clips af¿xed joint cover can also be supplied powder-coated, upon request, in any RAL colour. All models can be supplied mill or anodised ¿nished. Non standard lengths and drilled pro¿les can be supplied on special orders. *Please contact us for quantities and conditions. Extruded PVC The extruded PVC clips af¿xed joint covers can be used for exteriors and interiors. The colours white RAL 9016, cream RAL 1015 and grey RAL 7035 are available from stock in lengths of 3 meters and in 50 mm, 70 mm and 90 mm wide, Àat and angle models. Please contact us for any special model or colour. Extruded Brass The extruded brass clips af¿xed joint covers are manufactured from CW 620 N (ASTM C 38000) alloy. Th
ey are available from stock in lengths of 3 meters and in 90 mm wide, Àat model only. Polishing can be made upon request.
4. Clips af¿xed joint cover in place
2. Insert head of the following clip alternatively
3. Push ¿rmly into joint
RAL colours Choice of clips afÀxed joint covers
Clip S: will af¿x pro¿les onto structural gaps varying in widths between 10 mm and 35 mm
clip L
2 models
The extruded clips af¿xed joint covers will successfully cover joints from 10 mm to 150 mm and are af¿xed by using specially developed spring clips. The Àat joint covers for façades, walls and ceilings are referenced as W pro¿les. The Àat joint covers for light Àoors and heavy duty Àoors are respectively referenced as LF and F pro¿les. The F pro¿les (F 060, F 070) have been developed to withstand heavy pedestrian traf¿c and light vehicles up to a maximum axle load of 6 kN. The letter E always denotes a corner pro¿le: EW - ELF. The number which follows the letter(s) always indicate
s the width of the joint covers in mm.
Clip L : will af¿x
pro¿les onto structural gaps varying in widths between 35 mm and 70 mm
Fixing clips
The joint covers can be af¿xed by using specially designed spring clips manufactured from tempered stainless steel which do not corrode and remain permanently Àexible without loss of back pressure, thus providing an extremely positive ¿xing. Fixing clips do not require any additional ¿xing such as sealant or screws and plugs attachments. 4 models of ¿xing clips are available from stock and are used in accordance with the width of the structural gap. * These unique and particularly innovative clips are protected by international patents. Special models can be studied and manufactured for speci¿c situations such as chamfered joints. Please consult our technical department for more details.
Clip L *
Clip XL *: will af¿x
pro¿les onto structural gaps varying in widths between 60 mm and 110 mm
FOLDED JOINT COVERS
The folded joint covers
for façades, walls and ceilings, are used when a clips afÀxed proÀle cannot be installed. They can be Àxed using silicone, polyurethane or MS polymer sealant or mechanically Àxed using screws and plugs. The folded joint covers for Áoors are designed for heavy duty trafÀc Áoors. They have to be mechanically or chemically Àxed. Please contact us for assistance.
Clip XXL *: will af¿x
pro¿les onto structural gaps varying in widths between 100 mm and 150 mm
* patented models
The range of folded joint covers is available in galvanised steel ; mill ¿nish aluminium ; powder coated aluminium ; anodised aluminium ; stainless steel and in thickness varying from 5/10 mm to 30/10 mm. Hot Melt adhesive
ADHESIVE JOINT COVERS
Aluminium
Brass
The range of adhesive joint covers is adapted for concealing joints mainly in walls and Áoor where limited movements are expected. They are not recommended for exterior use. • Silver anodised ALUMINIUM The adhesive silver anodised aluminium jo
int covers are available in 60, 80 and 100 mm wide. They are supplied in standard lengths of 3 meters. • Polished BRASS with protection Àlm The adhesive polished brass joint covers are available in 50, 60, 80 and 100 mm wide. They are supplied in standard lengths of 3 meters, and 13/10 mm thickness.
Edition March 2011
Stainless steel
Release paper
• Polished STAINLESS STEEL with protection Àlm The adhesive polished stainless steel joint covers are available in 50, 60, 80 and 100 mm wide. They are supplied in standard lengths of 3 meters and 12/10 mm thickness.
© GV2 - 2010 - Tous droits réservés - All rights reserved
- GV2/VEDA FRANCE - 52, avenue Marcel Paul - 93297 Tremblay en France Cedex - Tel : 33 (0)1 48 61 70 80 - Fax : 33 (0)1 48 61 70 81 E-mail : contact@vedafrance.com - web : www.vedafrance.com
VEDA FRANCE
CLIPS AFFIXED ALUMINIUM JOINT COVERS
L L
Fb
Fb
Clip S*: will affix profiles onto structural gaps varying in widths between 10 mm and 35 mm
Clip L*: will
affix profiles onto structural gaps varying in widths between 35 mm and 70 mm
Clip XL*: will affix profiles onto structural gaps varying in widths between 60 mm and 110 mm
Clip XXL*: will affix profiles onto structural gaps varying in widths between 100 mm and 150 mm
*
Patented models
Joint width Fb (mm) 10 - 35 20 - 40 35 - 50 40 - 70 60 - 90 80 - 110 100 - 130 120 - 150
Flat joint covers L (mm) W W W W W W W W LF LF LF LF LF LF LF LF 050 - F 060 - F 070 090 120 140 180 210
Angle joint covers L (mm) EW EW EW EW EW ELF ELF ELF ELF ELF 050 060 070 090 120
Recommended clip S S/L S/L L / XL L / XL XL XL / XXL XXL
Number of clips by length of 3 lm Floor Wall / Ceiling 10 4 4 10 4 10 4 10 4 10 4/5 10 10 4/5 10 4/5
Note:The above table indicates the minimum width of joint cover (L dimension) recommended according to the initial width of the structural gap (Fb). A 70 mm wide joint cover is recommended to cover a structural gap of 35-50 mm. Of course a joint cover wider than 70 mm c
an also be used: 90 mm, 120 mm, 140 mm,180 mm, 210 mm. In order to avoid any mistake, it is important to check that the selected models of joint covers and clips are adapted to the concerned situation on job site. NUMBER OF CLIPS FOR ALUMINIUM JOINT COVERS: Wall / Ceiling: it is recommended to use minimum 4 clips per 3 lm length (joint covers ref.W and EW).Extra clips may be needed for fixing onto ceilings and irregular walls. Floor: it is recommended to use minimum 10 clips per 3 lm length (joint covers ref. LF, F and ELF) CHEMICAL COMPOSITION OF ALUMINIUM ALLOY 6063 T6 % Minimum Maximum Si 0.20 Fe 0.35 Cu 0.10 Mn 0.10 Mg 0.45 0.90 Cr 0.10 Zn 0.10 Ti 0.10 Others 0.05
23.4 0.33 200 3.3 940
CERTIFICATIONS : - extruded aluminium: manufactured in compliance with BS EN ISO 9001. Anodising according to BS 1615 and BS 3987 - Stainless steel clips: certifications ISO 14001 – ISO/TS 16949 – ISO 9001
GV2/VEDA FRANCE - 52, avenue Marcel Paul - 93297 Tremblay en France cedex - Tél. : 33 (0
)1 48 61 70 80 - Fax : 33 (0)1 48 61 70 81 E-mail : contact@vedafrance.com - Web : www.vedafrance.com
April 07 - Springer & Co - No contractual document
TYPICAL PHYSICAL PROPERTIES Density g/cm3 Melting range °C Coefficient of linear expansion (0 to 100°C) -°C-1x106 Poisson ratio Thermal conductivity Resistivity at 20°C – 1 1 cm Specific heat J / kg°C
2.70 615-655
MECHANICAL PROPERTIES AT ROOM TEMPERATURE Temper T6 Strength index R19 Tensile properties Rp 0.2 mini Rm mini A 5.65 0.2%min. UTS min. % mini MPa MPa 160 185 8
VEDA FRANCE
L
CLIPS AFFIXED PVC JOINT COVERS
L
Fb Fb
Clip S*: will affix profiles onto structural gaps varying in widths between 10 mm and 35 mm
Clip L*: will affix profiles onto structural gaps varying in widths between 35 mm and 70 mm
Clip XL*: will affix profiles onto structural gaps varying in widths between 60 mm and 110 mm
*
Patented models
Joint width Fb (mm) 10 20 35 40 35 40 50 70
Flat joint covers L (mm) W W W W LF LF LF LF 050 060 070 0
90
Angle joint covers L (mm) EW - ELF 050 EW - ELF 060 EW - ELF 070 EW - ELF 090
Recommended clip S S/L S/L L / XL
Number of clips by length of 3 lm Wall / Ceiling Pedestrian Floor 10 5 5 10 10 5 5 10
The colours white RAL 9016, cream RAL 1015 and grey RAL 7035 are available from stock in lengths of 3 meters and in 50 mm, 70 mm and 90 mm wide, flat and angle models. In order to avoid any mistake, it is important to check that the selected models of joint covers and clips are adapted to the concerned situation on job site. TECHNICAL CHARACTERISTICS Density Vicat fusion point Modulus of elasticity Tensile strength Ball hardness Water absorption Bending stress Elongation Notch impact strength at 23 °C Linear tolerance Linear expansion coefficient Fire resistance 1.52 g/cm3 80°C 3200 N/mm 65 N/mm2 120 N/mm 0.04 % 92 N/mm 65 % 5.5 KJ/m 8 x 10 B2
-5 2 2 2 2
TEST METHOD DIN 53479 DIN 53460/B DIN 534457 DIN 53455 DIN 53446 DIN 53495 DIN 53452 DIN 53455 DIN 53453 DIN 16941
April 07 - Spr
90
Angle joint covers L (mm) EW - ELF 050 EW - ELF 060 EW - ELF 070 EW - ELF 090
Recommended clip S S/L S/L L / XL
Number of clips by length of 3 lm Wall / Ceiling Pedestrian Floor 10 5 5 10 10 5 5 10
The colours white RAL 9016, cream RAL 1015 and grey RAL 7035 are available from stock in lengths of 3 meters and in 50 mm, 70 mm and 90 mm wide, flat and angle models. In order to avoid any mistake, it is important to check that the selected models of joint covers and clips are adapted to the concerned situation on job site. TECHNICAL CHARACTERISTICS Density Vicat fusion point Modulus of elasticity Tensile strength Ball hardness Water absorption Bending stress Elongation Notch impact strength at 23 °C Linear tolerance Linear expansion coefficient Fire resistance 1.52 g/cm3 80°C 3200 N/mm 65 N/mm2 120 N/mm 0.04 % 92 N/mm 65 % 5.5 KJ/m 8 x 10 B2
-5 2 2 2 2
TEST METHOD DIN 53479 DIN 53460/B DIN 534457 DIN 53455 DIN 53446 DIN 53495 DIN 53452 DIN 53455 DIN 53453 DIN 16941