Instructiuni tehnice Multifix USF Tropical EN EJOT MULTIFIX® USF Tropical
Tip documentatie: Specificații tehnice
Salvează pdf
Full screen
EJOT MULTIFIX®
USF Tropical
Technical data sheet
EJOT SE & Co. KG ∙ Market Unit Construction ∙ In der Stockwiese 35 ∙ 57334 Bad Laasphe ∙ Germany
T +49 2752 9080 ∙ F +49 2752 908731 ∙ construction@ejot.com ∙ www.ejot.com/construction
EJOT MULTIFIX® USF Tropical
Content
General
3
Anchorage in concrete
5
Anchorage in masonry
11
Post-installed-rebar
18
Chemical resistance
24
Product description
Properties and benefits
Applications samples
Handling and storage
Applications and intended use
Mortar properties
Reactivity
Installation accessories - concrete
3
3
3
4
4
4
4
7
Installation instructions - concrete
Setting parameter - concrete
Recommended loads - concrete
Installation instructions
Installation parameters and accessories
Calculation of recommended loads
Recommended loads
Installation instruction - concrete
Cleaning and installation tools- concrete
Design anchorage and lap length
ETA
Application in
uncracked concrete
ETA
Application in
cracked
concrete
5
8
9
11
14
15
16
18
20
21
ETA
Application under
Seismic loading
ETA
Post-installed rebar
EJOT SE & Co. KG ∙ Market Unit Construction ∙ In der Stockwiese 35 ∙ 57334 Bad Laasphe ∙ Germany
T +49 2752 9080 ∙ F +49 2752 908731 ∙ construction@ejot.com ∙ www.ejot.com/construction
ETA
Application in
solid masonry
2
EJOT MULTIFIX® USF Tropical
General
Product description
The EJOT MULTIFIX® USF Tropical mortar is a 2-component reaction resin mortar based an Vinylester resin
styrene-free and will be delivered in a 2-c cartridge (SF - foil tube cartridge and ST - standard cartridge) system.
This cost-effective product may be used in combination with a hand-, battery- or pneumatic tool and a static
mixer. It was designed especially for the anchoring of threaded rods or reinforcing bars into concrete (also
porous and light). Based on the excellent standing behaviour the usability for overhead application is given.
The EJOT MULTIFIX® USF Tropical mortar p
roduct is characterised, by a huge range of applications including
seismic C1 + C2 with an installation temperature from +10 °C up to +45 °C.
Properties and benefits
> European Technical Assessment for bonded fasteners acc. to EAD 330499-01-0601 (Option 1, Seismic
C1 and C2): ETA-26/0193
> European Technical Assessment for post-installed
rebar acc. to. EAD 330087-00-0601: ETA-26/0194
> European Technical Assessment for metal injection
anchors for use in masonry acc. to
EAD 330076-01-0604: ETA-26/0195
> For heavy anchoring - doweling and post-installed
rebar connection
> Overhead application; waterfilled bore holes
> Suitable for attachment points with small edgeand axial distances due to an anchoring free of
expansion forces
> High chemical resistance
> Low odour
> High bending and pressure strength
> Cartridge can be reused up to the end of the shelf
life by replacing the static mixer or resealing cartridge with the sealing cap
Certifications
Application samples
Suitable for th
e fixation of facades, roofs, wood constructions, metal constructions; metal profils, columns,
beams, consoles, railings, sanitary devices, cable trays, piping, post-installed rebar connection (reconstruction
or reinforcement), etc.
EJOT SE & Co. KG ∙ Market Unit Construction ∙ In der Stockwiese 35 ∙ 57334 Bad Laasphe ∙ Germany
T +49 2752 9080 ∙ F +49 2752 908731 ∙ construction@ejot.com ∙ www.ejot.com/construction
3
EJOT MULTIFIX® USF Tropical
Handling and storage
> Storage: store in a cold and dark place, storage temperature: from +5 °C up to +25 °C
> Shelf life: 18 months for cartridges (ST), 12 months for foil tubes (SF)
Applications and intended use
> Base material:
cracked and uncracked concrete, light-concrete, porous-concrete, natural stone (Attention! natural stone, can
discolour; shall be checked in advance; hammer drilled bore holes,
> Anchor elements:
Threaded rods (zinc plated or hot dip, stainless steel and high corrosion resistance steel), r
einforcing bars,
profiled rod, steel section with undercuts (e.g. perforated section)
> Temperature range:
+10 °C up to 45 °C installation temperature
cartridge temperature min. +5 °C; up to 45 °C
10 °C to +80 °C base material temperature after full curing
Mortar properties
Properties
Test Method
Result
UV resistance
-
Pass
Watertightness
DIN EN 12390-8
0 mm
Temperature stability
-
120 °C
pH-value
-
> 12
Density
-
1.77 kg/dm³
Compressive strength
EN 196-1 Part 1
88 N/mm²
Flexural strength
EN 196-1 Part 1
15 N/mm2
E modulus
EN 12504-4
14000 N/mm2
Shrinkage
-
< 0.3 ‰
Hardness Shore D
-
90
Electrical resistance
IEC 93
3.6 109 W m
Thermal conductivity
IEC
0.65 W /m·K
Reactivity
Temperature
of base material
Gelling- and
working time
Full curing time in
dry base material1)
+ 10 °C to +14°C
30 min
5h
+ 15 °C to +19°C
20 min
210 min
+ 20 °C to +29°C
15 min
145 min
+ 30 °C to +34°C
10 min
80 min
+ 35 °C to +39°C
6 min
45 min
+ 40 °C to +44°C
4 min
25 min
+45 °C
2 min
20 min
Cartridge temperature
1)
+5 °C to +45 °C
The curing times in wet concrete has to be doubled.
EJOT SE & Co. KG ∙ Market Unit Construction ∙ In der Stockwiese 35 ∙ 57334 Bad Laasphe ∙ Germany
T +49 2752 9080 ∙ F +49 2752 908731 ∙ construction@ejot.com ∙ www.ejot.com/construction
4
EJOT MULTIFIX® USF Tropical
Anchorage in concrete
Installation instruction
Drilling of the bore hole
1a.
Drill with hammer drill a hole into the base material to the size and embedment depth required by the selected
anchor (see page 7 - 8).
In case of aborted drill hole: the drill hole shall be filled with mortar
Attention! Standing water must be removed before cleaning.
2a.
Starting from the bottom or back of the bore hole, blow the hole clean with compressed air (min. 6 bar)
or a hand pump (see page 7) a minimum of four times.
If the bore hole ground is not reached an extension shall be used.
The hand-pump ca
n be used for anchor sizes up to bore hole diameter 20 mm.
or
For bore holes lager then 20 mm or deeper 240 mm, compressed air
(min. 6 bar) must be used.
2b.
Check brush diameter (see page 7) and attach the brush to a drilling machine or a battery screwdriver. Brush the
hole with an appropriate sized wire brush > db,min (see page 7) a minimum of four times.
If the bore hole ground is not reached with the brush, a brush extension shall be used (see page 7).
2c.
Finally blow the hole clean again with compressed air (min. 6 bar) or a hand pump (see page 7) a minimum of
four times. If the bore hole ground is not reached an extension shall be used.
The hand-pump can be used for anchor sizes up to bore hole diameter 20 mm.
or
For bore holes larger than 20 mm or deeper 240 mm, compressed air (min. 6 bar ) must be used.
After cleaning, the bore hole has to be protected against re-contamination in an appropriate way, until dispensing the mortar in the bore hole. If necessary, the cleaning
has to be
repeated directly before dispensing the mortar. In-flowing water must not contaminate the bore hole again.
3.
Attach a supplied static-mixing nozzle to the cartridge and load the cartridge into the correct dispensing tool.
After every working interruption longer than the recommended working time (see page 4) as well as for new
cartridges, a new static-mixer shall be used.
EJOT SE & Co. KG ∙ Market Unit Construction ∙ In der Stockwiese 35 ∙ 57334 Bad Laasphe ∙ Germany
T +49 2752 9080 ∙ F +49 2752 908731 ∙ construction@ejot.com ∙ www.ejot.com/construction
5
EJOT MULTIFIX® USF Tropical
4.
Prior to inserting the anchor rod into the filled bore hole, the position of the embedment depth shall be marked
on the anchor rods.
5.
Prior to dispensing into the anchor hole, squeeze out separately a minimum of three full strokes and discard
non-uniformly mixed adhesive components until the mortar shows a consistent grey or blue colour. For foil tube
cartridges it
must be discarded a minimum of six full strokes.
6.
Starting from the bottom resp. back of the cleaned anchor hole fill the hole up to approximately two-thirds with
adhesive. Slowly withdraw of the static mixing nozzle as the hole is filled avoids creating air pockets. If the bore
hole ground is not reached with the static-mixing nozzle, a appropriate extension must be used. Observe the gel-/
working times given (see page 4).
7.
Piston plugs and mixer nozzle extensions shall be used according to
table page 7 for the following applications:
Horizontal assembly (horizontal direction) and ground erection (vertical downwards direction): Drill bit-Ø d0 ≥ 18
mm and embedment depth hef > 250mm
Overhead assembly (vertical upwards direction): Drill bit-Ø d0 ≥ 18 mm
8.
Push the threaded rod or reinforcing bar into the anchor hole while turning slightly to ensure positive distribution
of the adhesive until the embedment depth is reached.
The anchor should be free of dirt, grease, oil or
other foreign material.
9.
Be sure that the anchor is fully seated at the bottom of the hole and that excess mortar is visible at the top of the
hole. If these requirements are not maintained, the application has to be renewed.
For overhead application the anchor rod shall be fixed (e. g. wedges).
10.
Allow the adhesive to cure to the specified time prior to applying any load or torque. Do not move or load the
anchor until it is fully cured (see page 4).
11.
After full curing, the add-on part can be installed with the max. torque (see page 8) by using a calibrated torque
wrench.
EJOT SE & Co. KG ∙ Market Unit Construction ∙ In der Stockwiese 35 ∙ 57334 Bad Laasphe ∙ Germany
T +49 2752 9080 ∙ F +49 2752 908731 ∙ construction@ejot.com ∙ www.ejot.com/construction
6
EJOT MULTIFIX® USF Tropical
Installation accessories
CAC - Rec. compressed air tool (min 6 bar)
Drill bit diameter (d0): all diameters
MAC - Hand pump (volume 750 ml)
Drill bit diameter (d0): 10 m
m to 20 mm
Drill hole depth (h0): < 240 mm
db. min
min.
Brush-ø
Piston plug
Installation direction
and use of piston plug
[mm]
[mm]
[-]
RBT 10
12
10.5
RBT 12
14
12.5
16
RBT 14
16
14.5
16
RBT 16
18
16.5
Threaded
rod
Rebar
d0
Drill bit-ø
HD
db
Brush-ø
[mm]
[mm]
[mm]
[-]
M8
-
10
M10
8
12
M12
10
12
M16
hef>
250 mm
all
No piston plug required
14
18
RBT 18
20
18.5
VS 18
16
20
RBT 20
22
20.5
VS 20
M20
20
24
RBT 24
26
24.5
VS 24
M24
-
28
RBT 28
30
28.5
VS 28
M27
25
32
RBT 32
34
32.5
VS 32
M30
28
35
RBT 35
38
35.5
VS 35
32
40
RBT 40
41.5
40.5
VS 40
EJOT SE & Co. KG ∙ Market Unit Construction ∙ In der Stockwiese 35 ∙ 57334 Bad Laasphe ∙ Germany
T +49 2752 9080 ∙ F +49 2752 908731 ∙ construction@ejot.com ∙ www.ejot.com/construction
hef>
250 mm
7
EJOT MULTIFIX® USF Tropical
Setting parameter - concrete
Anchor size
M8
M10
M12
M16
M20
M24
Outdoor diameter of ancho
r
d = dnom
[mm]
8
10
12
16
20
24
Nominal drill hole diameter
d0
[mm]
10
12
14
18
24
28
hef.min
[mm]
60
60
70
80
90
96
hef.max
[mm]
160
200
240
320
400
480
Diameter of clearance hole
in the fixture
Pre-positioned
anchorage df ≤
[mm]
9
12
14
18
22
26
Maximum torque moment
Tinst≤
[Nm]
10
20
40
80
120
160
Effective embedment depth
Minimum thickness of member
hmin
[mm]
Minimum spacing
Smin
[mm]
40
50
60
80
100
120
Minimum edge distance
Cmin
[mm]
35
40
60
80
100
120
Ø8
Ø10
Ø12
Ø14
Ø16
Ø20
Ø25
Outdoor diameter of anchor
d = dnom
[mm]
8
10
12
14
16
20
25
Nominal drill hole diameter
d0
[mm]
12
14
16
18
20
25
32
hef.min
[mm]
60
60
70
75
80
90
100
hef.max
[mm]
160
200
240
280
320
400
500
Minimum thickness of member
hmin
[mm]
Minimum spacing
Smin
[mm]
50
55
65
70
80
100
130
Minimum edge distance
Cmin
[mm]
50
55
65
70
80
100
130
Rebar size
hef + 3
0 mm ≥ 100 mm
hef + 2d0
Effective embedment depth
hef + 30 mm ≥ 100 mm
hef + 2d0
EJOT SE & Co. KG ∙ Market Unit Construction ∙ In der Stockwiese 35 ∙ 57334 Bad Laasphe ∙ Germany
T +49 2752 9080 ∙ F +49 2752 908731 ∙ construction@ejot.com ∙ www.ejot.com/construction
8
EJOT MULTIFIX® USF Tropical
Recommended loads
Threaded rod
The recommended loads are only valid for single anchors for a basic design, if the following conditions
are valid:
c ≥ 1.5 x hef | s ≥ 3.0 x hef | h ≥ 2 x hef
Ψsus = 1.0; percentage of dead load ≤ Ψ0sus see table below
The recommended loads have been calculated using the partial safety factors for resistances stated
in the ETA(s) and with a partial safety factor for actions of γf = 1.4.
The partial safety factor for seismic action is γ1 = 1.0.
If the conditions are not fulfilled the loads must be calculated acc. to EN 1992-4.
For further details observe ETA-26/0193.
> Property class 8.8
> Concrete - C20/25
> Hammer dril
ling (HD)
> dry, wet concrete
Recommended tension load
uncracked
40 °C / 24 °C ¹)
Ψ0sus = 0.60
cracked
M8
M10
M12
M16
M20
M24
Nrec.stat
[kN]
6.8
9.0
13.2
19.9
33.9
50.3
Nrec.stat
[kN]
3.6
5.0
7.4
11.2
NPA
NPA
Nrec.eq.C1
[kN]
2.6
3.5
5.3
7.7
NPA
NPA
Nrec.eq.C2
[kN]
NPA
NPA
1.7
3.3
NPA
NPA
uncracked
Nrec.stat
[kN]
5.2
6.7
9.9
15.0
25.4
37.7
Nrec.stat
[kN]
2.8
3.9
5.8
8.7
NPA
NPA
cracked
Nrec.eq.C1
[kN]
2.1
2.8
4.1
6.1
NPA
NPA
Nrec.eq.C2
[kN]
NPA
NPA
1.4
2.6
NPA
NPA
Vrec.stat
[kN]
6.3
9.7
14.3
20.8
34.1
48.1
Vrec.stat
[kN]
6.3
8.4
11.7
14.8
NPA
NPA
Vrec.eq.C1
[kN]
4.2
5.8
8.5
12.5
NPA
NPA
Vrec.eq.C2
[kN]
NPA
NPA
2.8
5.3
NPA
NPA
Embedment depth
hef
[mm]
80
90
110
125
170
210
Edge distance
c≥
[mm]
120
135
165
187.5
255
315
Axial distance
s≥
[mm]
240
270
330
375
510
630
80 °C /50 °C 1)
Ψ0sus = 0.60
uncracked
Recommended shear
load without lever
arm
2) 3)
cracked
Short term temperature / long term temperature.
Shear loads are valid for all specified temperature ranges.
3)
In case of seismic action, the annular gap between the anchor rod and the through hole of the attachment must be filled with mortar, otherwise agap =
0.5 acc. to ETA-26/0193 must be taken into account.
Nrec.stat. Vrec.stat = Recommended load under static and quasi-static action
Nrec.eq. Vrec.eq = Recommended load under seismic action
NPA = no performance assessed
1)
2)
EJOT SE & Co. KG ∙ Market Unit Construction ∙ In der Stockwiese 35 ∙ 57334 Bad Laasphe ∙ Germany
T +49 2752 9080 ∙ F +49 2752 908731 ∙ construction@ejot.com ∙ www.ejot.com/construction
9
EJOT MULTIFIX® USF Tropical
Rebar
The recommended loads are only valid for single anchors for a basic design, if the following conditions
are valid:
c ≥ 1.5 x hef | s ≥ 3.0 x hef | h ≥ 2 x hef
Ψsus = 1.0; percentage of dead load ≤ Ψ0sus see table below
The recommended loads ha
ve been calculated using the partial safety factors for resistances stated
in the ETA(s) and with a partial safety factor for actions of γf=1.4.
If the conditions are not fulfilled the loads must be calculated acc. to EN 1992-4.
For further details observe ETA-26/0194.
Recommended tension load
> Property class BSt 500
> Concrete - C20/25
> Hammer drilling (HD)
> dry, wet concrete
Ø8
Ø10
Ø12
Ø14
Ø16
Ø20
Ø25
40 °C / 24 °C 1)
Ψ0sus = 0.60
uncracked
Nrec.stat
[kN]
5.6
7.9
11.5
14.0
16.2
27.6
42.5
80 °C / 50 °C 1)
Ψ0sus = 0.60
uncracked
Nrec.stat
[kN]
4.4
6.2
9.1
11.0
13.7
21.2
32.7
Recommended shear
load without lever
arm 2) 3)
uncracked
Vrec.stat
[kN]
6.7
10.5
14.8
18.0
20.8
34.1
48.4
hef
[mm]
80
90
110
115
125
170
210
Embedment depth
Edge distance
c≥
[mm]
120
135
165
172.5
187.5
255
315
Axial distance
s≥
[mm]
240
270
330
345
375
510
630
Short term temperature / long term temperature.
Shear loads are
valid for all specified temperature ranges.
Nrec.stat. Vrec.stat = Recommended load under static and quasi-static action
1)
2)
EJOT SE & Co. KG ∙ Market Unit Construction ∙ In der Stockwiese 35 ∙ 57334 Bad Laasphe ∙ Germany
T +49 2752 9080 ∙ F +49 2752 908731 ∙ construction@ejot.com ∙ www.ejot.com/construction
10
EJOT MULTIFIX® USF Tropical
Anchorage in masonry
Installation instruction
Preparation of cartridge
1.
Remove the cap and attach the supplied static-mixing nozzle to the cartridge and load the cartridge into the
correct dispensing tool. In case of a foil tube cartridge, cut off the clip before use. For every working interruption
longer than the recommended working time (see page 4) as well as for new cartridges, a new static-mixer shall
be used.
2.
Prior to inserting the anchor rod into the filled bore hole, the position of the embedment depth shall be marked
on the anchor rods.
3.
Prior to dispensing into the anchor hole, squeeze out separately a
minimum of three full strokes and discard nonuniformly mixed adhesive components until the mortar shows a consistent grey colour. For foil tube cartridges it
must be discarded a minimum of six full strokes.
Installation in solid masonry (without sleeve)
4.
Holes to be drilled perpendicular to the surface of the base material by using a hard-metal tipped hammer drill
bit. Drill a hole, with drilling method according to page 12, into the base material, with nominal drill hole diameter
and bore hole depth according to the size and embedment depth required by the selected anchor.
In case of aborted drill hole the drill hole shall be filled with mortar.
5a.
Holes to be drilled perpendicular to the surface of the base material by using a hard-metal tipped hammer drill
bit. Drill a hole, with drilling method according to page 12, into the base material, with nominal drill hole diameter
and bore hole depth according to the size and embedment depth required by the selected anchor.
In case of
aborted drill hole the drill hole shall be filled with mortar.
5b.
Attach an appropriate sized wire brush > db,min (see page 12) to a drill or a cordless screwdriver and brush the
hole clean with a minimum of two times in a twisting motion. If the bore hole ground is not reached
with the brush, a brush extension must be used.
5c.
Finally blow the hole clean again with handpump (see page 12) a minimum of two times.
EJOT SE & Co. KG ∙ Market Unit Construction ∙ In der Stockwiese 35 ∙ 57334 Bad Laasphe ∙ Germany
T +49 2752 9080 ∙ F +49 2752 908731 ∙ construction@ejot.com ∙ www.ejot.com/construction
11
EJOT MULTIFIX® USF Tropical
6.
Starting from the bottom resp. back of the cleaned anchor hole fill the hole up to approximately two-thirds with
adhesive. Slowly withdraw of the static mixing nozzle as the hole is filled avoids creating air pockets.
Observe the gel-/ working times given (see page 4).
7.
Push the threaded rod or reinforcing bar into the anchor hol
e while turning slightly to ensure positive distribution
of the adhesive until the embedment depth is reached. The anchor should be free of dirt, grease, oil or other
foreign material.
8.
Allow the adhesive to cure to the specified time prior to applying any load or torque. Do not move or load the
anchor until it is fully cured. (see page 4).
9.
Allow the adhesive to cure to the specified time prior to applying any load or torque. Do not move or load the
anchor until it is fully cured. (see page 4).
10.
After full curing, the fixture can be installed with up to the max. installation
torque (see page 16 - 17) by using a calibrated torque wrench
Installation in solid and hollow masonry (with sleeve)
4.
Holes to be drilled perpendicular to the surface of the base material by using a hard-metal tipped hammer drill
bit. Drill a hole, with drill method according to page 12, into the base material, with nominal drill hole diameter
and bore hole depth according to the size and embedment d
epth required by the selected anchor. In case of
aborted drill hole the drill hole shall be filled with mortar
5a.
Starting from the bottom or back of the bore hole, blow the hole clean with handpump (see page 12) a minimum
of two times.
5b.
Attach an appropriate sized wire brush > db,min (see page 12) to a drill or a cordless screwdriver and brush the
hole clean with a minimum of two times in a twisting motion. If the bore hole ground is not reached with the
brush, a brush extension must be used.
EJOT SE & Co. KG ∙ Market Unit Construction ∙ In der Stockwiese 35 ∙ 57334 Bad Laasphe ∙ Germany
T +49 2752 9080 ∙ F +49 2752 908731 ∙ construction@ejot.com ∙ www.ejot.com/construction
12
EJOT MULTIFIX® USF Tropical
5c.
Finally blow the hole clean again with handpump (see page 12) a minimum of two times.
6.
Insert the perforated sleeve flush with the surface of the masonry or plaster. Only use sleeves that have the right
length. Never cut the sleeve. For installat
ion through insulation the sleeve SH 16x130/330 shall be cutted at the
top end according to the insulation thickness.
7.
Starting from the bottom or back fill the sleeve with adhesive. For quantity of mortar attend cartridges label or
installation instructions. Obeserve the gel-/working times given in table on page 4.
8.
Push the threaded rod into the anchor hole while turning slightly to ensure positive distribution of the adhesive
until the embedment depth is reached. The anchor shall be free of dirt, grease, oil or other foreign material.
9.
Allow the adhesive to cure to the specified curing time prior to applying any load or torque. Do not move or load
the anchor until it is fully cured (attend tables on page 4).
10.
After full curing, the fixture can be installed with up to the max. installation torque (see parameters of brick on
page 16 - 17) by using a calibrated torque wrench.
EJOT SE & Co. KG ∙ Market Unit Construction ∙ In der Stockwiese 35 ∙ 57334 Bad Laasphe ∙
Germany
T +49 2752 9080 ∙ F +49 2752 908731 ∙ construction@ejot.com ∙ www.ejot.com/construction
13
EJOT MULTIFIX® USF Tropical
Installation parameters and accessories
Solid brick and autoclaved aerated concrete
M8
M10
M12
M16
Nominal drill hole diameter
d0
[mm]
10
12
14
18
Effective anchorage depth
hef
[mm]
80
90
100
100
Drill hole depth
h0
[mm]
80
90
100
100
Minimum wall thickness
hmin
[mm]
hef + 30
Diameter of clearance hole in the fixture
df
[mm]
9
12
14
18
Diameter of steel brush
db ≥
[mm]
RBT10
RBT12
RBT14
RBT18
Min. brush diameter
db, min
[mm]
10.5
12.5
14.5
18.5
Max. installation torque
Tinst,max
[Nm]
see tables on page 16 - 17
Hollow brick and solid brick with sleeve
M8
M8/M10
M12/M16
Perforated sleeve
SH12x80
SH16x85
SH16x1301)
SH16x3301)
SH20x85
SH20x130
SH20x200
Nominal drill hole diameter
d0
[mm]
12
16
16
16
20
20
20
Effective anchorage depth
hef
[mm]
80
85
130
130
85
130
200
Drill hole depth
h0
[mm]
85
90
135
135 +tfix 1)
90
135
205
Minimum wall thickness
hmin
[mm]
115
115
175
175
115
175
240
Diameter of clearance hole in the fixture
df
[mm]
9
9 (M8) / 12 (M10)
14 (M12) / 18 (M16)
Diameter of steel brush
db ≥
[mm]
RBT12
RBT16
RBT16
RBT16
RBT20
RBT20
RBT20
Min. brush diameter
db, min
[mm]
12.5
16.5
16.5
16.5
20.5
20.5
20.5
Max. installation torque
Tinst,max
[Nm]
1)
see tables on page 16 - 17
tfix < 200 mm
MAC - Hand pump (volume 750 ml)
Steel brush RBT and brush extension
SDS Plus Adapter
EJOT SE & Co. KG ∙ Market Unit Construction ∙ In der Stockwiese 35 ∙ 57334 Bad Laasphe ∙ Germany
T +49 2752 9080 ∙ F +49 2752 908731 ∙ construction@ejot.com ∙ www.ejot.com/construction
14
EJOT MULTIFIX® USF Tropical
Calculation of recommended loads
The recommended loads given are for preliminary planning purposes only
and do not replace dimensioning.
The following conditions must be me
t:
>
>
>
>
>
>
>
>
>
>
>
>
Dry environment
Temperature range 24/40°C (long-term/short-term)
Spacing distance s ≥ scr
Edge distance c ≥ ccr
Strength class of masonry mortar at least M2.5
Brick strength as well as density and dimensions
Joints are visible
Vertical joint is mortared
Strength clas of the threaded rod is min. 5.8 oder higher
Drilling method:
„rotary drilling“ in hollow brick and autoclaved aerated concrete (AAC),
„hammer drilling“ in solid brick
The recommended loads take into account all partial safety factors (resistance 2.5; action 1.4)
and all failure modes. An interaction between tension and transverse tension was not taken into
account.
If one or more of the conditions listed above are not fulfilled, the application must be recalculated
according to TR054 and the requirements of the relevant ETA.
EJOT SE & Co. KG ∙ Market Unit Construction ∙ In der Stockwiese 35 ∙ 57334 Bad Laasphe ∙ Germany
T +49 2752 9080 ∙ F +49 2752 908731 ∙ const
t:
>
>
>
>
>
>
>
>
>
>
>
>
Dry environment
Temperature range 24/40°C (long-term/short-term)
Spacing distance s ≥ scr
Edge distance c ≥ ccr
Strength class of masonry mortar at least M2.5
Brick strength as well as density and dimensions
Joints are visible
Vertical joint is mortared
Strength clas of the threaded rod is min. 5.8 oder higher
Drilling method:
„rotary drilling“ in hollow brick and autoclaved aerated concrete (AAC),
„hammer drilling“ in solid brick
The recommended loads take into account all partial safety factors (resistance 2.5; action 1.4)
and all failure modes. An interaction between tension and transverse tension was not taken into
account.
If one or more of the conditions listed above are not fulfilled, the application must be recalculated
according to TR054 and the requirements of the relevant ETA.