• When the door is installed against a wall on the cool side, the folding space on the hot side must be increased by ... Vezi tot
• When the door is installed against a wall on the cool side, the folding space on the hot side must be increased by at least 100 mm to avoid fabric wear. • The motor should be placed on the cool side.A heat radiation shield below the motor may be necessary. • All cables must be protected. • The clear height should be as large as possible. Note! Must always be quoted by Megadoor. Specifications 16 Megadoor S1500 Vertical lifting fabric door 2.4.1.6 Product datasheet Heat resistant fabric - Polyurethane coating Application Fire barrier Use On the inside of the door (never on the outside) on the outside of the standard fabric. Designation W2167 Gp2 Coating Two sides aluminium grey polyurethane Thickness 0.8 mm Fabric Woven glass fibre, Atlas 1/8 Weight 690 g/m² Heat resistance +450°C Tensile strength Warp : 1350N/cm acc. EN ISO 13934-1 Weft : 1260N/cm acc. EN ISO 13934-1 Fire classification Incombustible according to M0 (French standard) Note! Must ... ascunde