Sisteme de panouri pentru fatade ventilate, tipuri de imbinari ale panourilor TRESPA

Tip documentatie: Fisa tehnica
Denumiri comerciale: METEON

Marca:
TRESPA
Sus
TRESPA METEON Joints The following guidelines apply to joints and panel connections: I The panels should be able to... Citeste tot textul din documentatie
TRESPA METEON Joints The following guidelines apply to joints and panel connections: I The panels should be able to move 2.5 mm per metre in the length and the width. Therefore sufficient space should be allowed for around the panels. I Panel, assembly and building tolerances play an important role in the joint details. The panels should also be able to move. Therefore a minimum joint width of 10 mm is required. I The joints should be such that sufficient ventilation and/or drainage is ensured in order to prevent damage as a result of retained moisture. I Insects and vermin may nestle behind the façade cladding. Joints that are larger than 10 mm should therefore be fixed with grilles, wire netting, etc. Open joints The panel connections may either be open or sealed. If an open joint system is used for vertical and/or horizontal joints, specific attention should be paid to possible rain or moisture penetration. When the insulation becomes wet the insulation value decreases so no longe ... ascunde
Ce parere ai? Logheaza-te ca sa poti comenta: